Related Experiment Video
Updated: Jul 19, 2026

Quantifying X-Ray Fluorescence Data Using MAPS
Published on: February 17, 2018
A versatile technique for the investigation of gunshot residue patterns on fabrics and other surfaces: m-XRF
Antje Berendes1, Dieter Neimke, Rüdiger Schumacher
1Bundeskriminalamt, Forensic Science Institute, KT 23-Schussspuren, Thaerstrasse 11, D-65173 Wiesbaden, Germany. antje.berendes@bka.bund.de
Abstract:
With heavy-metal-free ammunitions becoming more and more popular, it is necessary to find methods to visualize patterns of those elements in gunshot residues (GSRs) that are not accessible by chemographic coloring tests. The recently introduced millimeter-X-ray fluorescence analysis (m-XRF) spectrometer Spectro Midex M offers an easy way to record mappings of GSRs containing such elements in order to determine shooting distances as well as the general composition of these particles. A motorized stage enables samples of a maximum size of 20 x 20 cm to be investigated, like fabric, clothes, adhesive tapes (Filmolux films), and polyvinylalcohol gloves of shooter's hands. Human tissues can be measured using a Peltier-cooled specimen holder that is mounted onto the stage. As the spot size of the exiting X-rays lies in the millimeter range, which is adequate for the assessment of the residue patterns for shooting distance determination, a significant reduction in measurement time is achieved compared with mu-XRF methods. Test shots with heavy-metal-free ammunitions were performed on different target materials, like pork skin and fabric, and the elemental distributions of Ti, K, and Ga were determined. In order to show the capability of the spectrometer for conventional lead ammunitions as well, a shot series of 5-100 cm shooting distance and an adhesive tape of a shooter's hand were investigated analogously. A comparison of several methods applied in GSR investigation shows the advantages of the m-XRF method.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
MALDI-TOF Mass Spectrometry
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Atomic Fluorescence Spectroscopy
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation

