Related Experiment Video
Updated: Jul 19, 2026

Closure of a Patent Foramen Ovale (PFO): An Intervention Sequence
Published on: December 23, 2022
Profound hypoxaemia corrected by PFO closure device in carcinoid heart disease
Philip M Mottram1, David J McGaw, Ian T Meredith
1Monash Medical Centre, Department of Cardiology, Melbourne, Australia. philip.mottram@med.monash.edu.au
Abstract:
A 66-year-old man with known metastatic carcinoid tumor presented with increasing dyspnoea, right heart failure and marked hypoxaemia which did not correct with oxygen. Echocardiography demonstrated severe tricuspid regurgitation, moderate pulmonary regurgitation and marked right heart dilatation. The inter-atrial septum was aneurysmal, with a large patent foramen ovale (PFO) with continuous right to left shunting. Cardiac catheterization demonstrated oxygen saturations of 96% in the pulmonary veins and 74% in the left atrium with a significant right to left shunt. During percutaneous closure of the PFO, anaesthetic induction resulted in marked systemic hypotension and worsening hypoxia related to systemic vasodilatation and increased shunting. PFO flow was temporarily obstructed with a sizing balloon resulting in a rapid increase in arterial oxygen saturation from 60% to >90%, but marked systemic hypotension due to acute left ventricular preload reduction, requiring volume replacement and adrenaline. Following deployment of a PFO occluder device, prominent pulsatile splaying of the right and left discs was noted due to the severe tricuspid regurgitation, resulting in some residual inter-atrial shunting. Arterial oxygen saturation was 83%, increasing to 92% at day 4 post-procedure as tissue organization occurred within the device, and the patient reported improvement in dyspnoea.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Pneumothorax II: Pathophysiology
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Acute Respiratory Failure-III
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...