Related Experiment Video
Updated: Jul 19, 2026

Continuous-wave Thulium Laser for Heating Cultured Cells to Investigate Cellular Thermal Effects
Published on: June 30, 2017
Hand-held pulsed photothermal radiometry system to estimate epidermal temperature rise during laser therapy
Byungjo Jung1, Chang-Seok Kim, Bernard Choi
1Beckman Laser Institute, Irvine, CA, USA. bjung@dragon.yonsei.ac.kr
Background/Purpose:
During laser therapy of port wine stain (PWS) birthmarks in human skin, measurement of the epidermal temperature rise (DeltaT(epi)) is important to determine the maximal permissible light dose. In order to measure DeltaT(epi) on a specific PWS skin site, we developed an AC-coupled hand-held pulsed photothermal radiometry (PPTR) system, which overcomes the in vivo measurement limitations of bench-top systems.
Methods:
The developed hand-held PPTR system consists of an infrared (IR) lens, AC-coupled thermoelectrically cooled IR detector, laser hand-piece holder, and positioning aperture. The raw AC-coupled signal was integrated to obtain a higher signal-to-noise ratio (SNR). The experimental temperature difference (DeltaT) calibration was compared with theoretical computations. In vitro and in vivo measurements of DeltaT were performed with a tissue phantom as a function of radiant exposure and human subject as a function of melanin concentration, respectively.
Results:
The integrated AC-coupled signal provided higher SNR as compared with the raw AC-coupled signal. The experimental DeltaT calibration resulted in good agreements with the theoretical results. The in vitro and in vivo results also presented good agreements with theory.
Conclusions:
A fiber-free, hand-held AC-coupled PPTR system is capable of accurate epidermis temperature rise (DeltaT(epi)) measurements of human skin during pulsed laser exposure.
More Related Videos
09:01Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
09:23Inducing Targeted Mild Hyperthermia in Murine Tumor Models through Photothermal Conversion of Near-infrared Light by Intratumoral Gold Nanorods
Published on: October 10, 2025
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...