Related Experiment Video
Updated: Jul 19, 2026

A New Murine Model of Endovascular Aortic Aneurysm Repair
Published on: July 7, 2013
Late perforation of a thoracic aortic dacron graft by a metallic stent-graft component
Octavio Cosin1, Hervé Rousseau, Phillipe Otal
1Service de Radiologie, Hôpital Rangueil, Toulouse, France. ocosin@unav.es
Purpose:
To describe a case involving perforation of a previously placed aortic Dacron graft by the uncovered proximal stent of a thoracic stent-graft.
Case Report:
A 76-year-old man with a surgically treated type A dissection presented with residual type B dissection. Thoracic stent-grafting of the entry site was performed successfully. After 2 years, the patient was admitted for evaluation of a non-pulsating parasternal mass. Computed tomography showed a large, hypodense liquid-like mass affecting the mediastinum up to the subcutaneous tissue. A false aneurysm at the proximal end of the stent-graft was observed arising from an aortic perforation by the uncovered stent. One week later, the mass had almost completely resolved, and the patient has been scheduled for close surveillance.
Conclusion:
This case illustrated the importance of thoroughly examining the long-term durability and compatibility of prosthetic materials.
Related Concept Videos
Aneurysm III: Interprofessional Care
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus.
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations: