Related Experiment Video
Updated: Jul 19, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Reference values in white Europeans for the arterial pulse wave recorded by means of the SphygmoCor device
Wiktoria Wojciechowska1, Jan A Staessen, Tim Nawrot
1First Cardiac Department, Jagiellonian University Medical College, Cracow, Poland.
Abstract:
Measurement of blood pressure together with applanation tonometry at the radial artery allows the reproducible assessment of various indexes of arterial stiffness, including the peripheral (PPp) and central pulse pressures (PPc) and the peripheral (Alp) and central augmentation indexes (Alc). We defined preliminary diagnostic thresholds, using the distributional characteristics of these hemodynamic measurements in a reference population. We randomly recruited 870 subjects from 3 European populations. PPp was the average difference between systolic and diastolic blood pressure measured five times at one home visit. For measurement of PPc, Alp and Alc, we used the SphygmoCor device. We selected subjects without hypertension, diabetes, dyslipidemia in need of medical treatment or previous or concomitant cardiovascular disease. The study population included 228 men and 306 women (mean age 34.9 years). All hemodynamic measurements were curvilinearly related to age, and Alp and Alc were lower in men than in women. In men at age 40, the upper 95% prediction bands of the relations of the hemodynamic measurements with age approximated 60 mmHg for PPp, 40 mmHg for PPc, 90% for Alp, and 30% for Alc. For PPc, Alp and Alc, these thresholds must be adjusted for age, leading to lower and higher thresholds at younger and older age, respectively. In addition, in women of any age, the Alp and Alc thresholds must be increased by 10% and 7%, respectively. Pending validation in prospective outcome studies, distributional characteristics of arterial stiffness indexes in a reference population can be used to generate operational thresholds for use in clinical practice.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring pulse
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
