Initial clinical experience with rate adaptive cardiac pacing using two sensors simultaneously.

M A Landman1, P J Senden, H van Rooijen

  • 1Eemland Hospital, Amersfoort, The Netherlands.

Pacing and Clinical Electrophysiology : PACE
|December 1, 1990
PubMed
Summary

This study combined QT interval and activity sensors in pacemakers for improved rate response. The dual-sensor system demonstrated more physiological heart rate adjustments during exercise and recovery compared to single sensors.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Left ventricular false tendons.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2021
Same author

Training general practitioners to improve evidence-based drug treatment of patients with heart failure: a cluster randomised controlled trial.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2020
Same author

Trends in replacement of pacemaker leads in the Netherlands: A long-term nationwide follow-up study.

Pacing and clinical electrophysiology : PACE·2018
Same author

Trends in service time of pacemakers in the Netherlands: a long-term nationwide follow-up study.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2017
Same author

Utilisation of cardiac pacemakers over a 20-year period: Results from a nationwide pacemaker registry.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2016
Same author

Acoustic shock waves, a new weapon against angina?

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2016

Area of Science:

  • Biomedical Engineering
  • Cardiovascular Technology
  • Implantable Devices

Background:

  • Existing rate-adaptive pacemakers have limitations with single sensor functionalities.
  • Optimizing pacemaker rate response is crucial for patient well-being during physical activity.

Purpose of the Study:

  • To evaluate the rate-adaptive performance of a novel pacemaker system utilizing both QT interval and activity sensors.
  • To compare the efficacy of the dual-sensor system against single-sensor (QT interval or activity) modes.

Main Methods:

  • A two-sensor pacemaker algorithm integrating QT interval and activity data was developed.
  • Nine patients underwent three exercise stress tests using an implanted QT sensor and an external activity sensor.
  • Real-time data was transmitted to a computer for algorithm processing and pacemaker reprogramming.

Related Experiment Videos

Main Results:

  • The dual-sensor mode exhibited an immediate heart rate increase at exercise onset, driven by the activity sensor.
  • Subsequent rate increases were proportional to exercise intensity, modulated by the QT interval sensor.
  • Heart rate recovery post-exercise was more physiological in the two-sensor mode.

Conclusions:

  • Combining QT interval and activity sensors significantly enhances pacemaker rate-adaptive capabilities.
  • The dual-sensor approach offers a more responsive and natural heart rate regulation during physical exertion and recovery.
  • This integrated system addresses drawbacks of current single-sensor pacemaker technologies.