Related Experiment Video
Updated: Jul 19, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Temperature dependence of acidity constants, a tool to affect separation selectivity in capillary electrophoresis
Jetse C Reijenga1, Leonardo G Gagliardi, Ernst Kenndler
1Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, The Netherlands.
Abstract:
The mathematical models of migration and dispersion in capillary zone electrophoresis of small molecules form a sound basis for separation strategies of complex mixtures. It turned out that the key property is the effective mobility of the sample ions. To tune resolution parameters such as pH, complexation constants and ionic strength are widely used; temperature however is not although mobilities and pK(a) values depend in a more or less degree on temperature. From the temperature dependences of pK(a) values of a number of compounds listed in the literature a general rule can be derived: for carboxylic and inorganic acids dpK(a)/dT values are very small and the pK(a) values change less than +/-0.05 units/10K. Thermodynamically speaking, these compounds exhibit dissociation enthalpies close to zero. Phenols and amines, on the other hand, have systematically larger dpK(a)/dT values of about -0.1 to -0.2 units per 10K (the results of dissociation enthalpies of 20-70 kJ/mole). Based on this classification, a distinction can be made between different situations in capillary electrophoresis: (i) selectivity changes with temperature are largely due to the temperature dependence of the pK(a) of the buffering compound in the background electrolyte, (ii) selectivity changes mainly result from the temperature dependence of the pK(a) of the sample ions, and (iii) temperature effects on the pK(a) values of both, sample and buffer play a role. This work demonstrates such effects on selectivity in capillary electrophoresis highlighting the fact that in some instances temperature can be used to fine-tune separations.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Electrophoresis: Overview
There...
Relative Strengths of Conjugate Acid-Base Pairs
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...