Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt
1Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany. mathias.anton@ptb.de
Abstract:
In radiation therapy, the effect of ionizing radiation is quantified in terms of the absorbed dose to water. Dosimetry with alanine and readout via electron spin resonance (ESR) is a method which is used as a secondary standard by several national metrology institutions. The advantages of the method are the good water-equivalence of the probes, their small size and the very weak dependence of the response on the radiation quality for MV x-rays and high-energy electrons used in radiation therapy. For radiation therapy, a small uncertainty of the applied dose is required. The present publication describes the determination of the uncertainty budget for the alanine/ESR dosimetry system of the Physikalisch-Technische Bundesanstalt (PTB), which relies on the use of a reference sample. A method is also presented which allows a reduction of the influence of fading or other changes of the ESR amplitude of irradiated alanine probes with time. If certain conditions are met which are described in detail, a relative uncertainty of less than 0.5% can be reached for probes irradiated with (60)Co in the 5-25 Gy dose range, including the uncertainty of the primary standard. First results for dose values between 2 Gy and 10 Gy are presented as well. From the high accuracy achievable with alanine dosimetry, we conclude that this method has great potential to solve measurement problems for modern methods of radiation therapy such as intensity modulated radiation therapy (IMRT) or tomotherapy.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Biological Effects of Radiation
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...