Related Experiment Video
Updated: Jul 19, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Instrumental method for automated on-line fraction analysis and peak deconvolution in multicomponent-overloaded
Alberto Cavazzini1, Valentina Costa, Giorgio Nadalini
1Department of Chemistry, University of Ferrara Via L. Borsari 46, 44100 Ferrara, Italy. cvz@unife.it <cvz@unife.it>
Abstract:
A bi-dimensional (non-orthogonal) chromatographic system made of two columns of different length (longer along the first direction and shorter on the second) but packed with identical (or similar) materials has been employed to perform automated on-line fraction analysis and peak deconvolution of multicomponent overloaded band profiles. Multicomponent overloaded peaks, eluted from the first column, are sampled through a remotely-controlled switching valve and fractions are injected, under analytical conditions, directly into the second direction. This set-up serves a twofold purpose. First of all, it has been possible to use linear calibration curves for detector calibration (DC). Secondly, since single component peaks were resolved on the second direction, individual concentration profiles have been obtained beneath the envelop of overlapping bands. All the information necessary to operate the bi-dimensional system can be achieved by analyzing the chromatographic behavior of the mixture on the shorter column under linear conditions. Therefore, solutions of unknown concentration can be prepared and their composition reconstructed with a simple chromatographic run. Two- and three-component overloaded mixtures have been employed to validate the system.
More Related Videos
07:45Technical Approach for Structural Analysis of an Unknown Compound in Huoxiang Zhengqi Oral Liquid based on Linear Ion Trap Mass Spectrometry
Published on: April 3, 2026
07:11Automated HPLC Separation Using LC-Mate: An Integrated Repetitive Autosampler and Fraction Collector for Microscale Purification
Published on: February 27, 2026
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...