Generation of hydrophilic poly(dimethylsiloxane) for high-performance microchip electrophoresis
Jonathan A Vickers1, Meghan M Caulum, Charles S Henry
1Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523-1872, USA.
Abstract:
Poly(dimethylsiloxane) (PDMS) has become one of the most widely used materials for microchip capillary electrophoresis and microfluidics. The popularity of this material is the result of its low cost, simple fabrication, and rugged elastomeric properties. The hydrophobic nature of PDMS, however, limits its applicability for microchip CE, microfluidic patterning, and other nonelectrophoresis applications. The surface of PDMS can be made hydrophilic using a simple air plasma treatment; however, this property is quickly lost through hydrophobic recovery caused by diffusion of unreacted oligomer to the surface. Here, a simple approach for the generation of hydrophilic PDMS with long-term stability in air is presented. PDMS is rendered hydrophilic through a simple two-step extraction/oxidation process. First, PDMS is extracted in a series of solvents designed to remove unreacted oligomers from the bulk phase. Second, the oligomer-free PDMS is oxidized in a simple air plasma, generating a stable layer of hydrophilic SiO2. The conversion of surface-bound siloxane to SiO2 was followed with X-ray photoelectron spectroscopy. SiO2 on extracted-oxidized PDMS was stable for 7 days in air as compared to less than 3 h for native PDMS. Furthermore, the contact angle for modified PDMS was reduced to <40 degrees and remained low throughout the experiments. As a result of the decreased contact angle, capillary channels self-wet through capillary action, making the microchannels much easier to fill. Finally, the modification significantly improved the performance of the devices for microchip electrophoresis. The electroosmotic flow increased from 4.1 x 10(-4) to 6.8 x 10(-4) cm(2)/V.s for native compared to oxidized PDMS. Separation efficiencies for electrochemical detection also increased from 50 000 to 400 000 N/m for a 1.1-nL injection volume. The result of this modification is a significant improvement in the performance of PDMS for microchip electrophoresis and microfluidic applications.
More Related Videos
11:08Generation of Size-controlled Poly (ethylene Glycol) Diacrylate Droplets via Semi-3-Dimensional Flow Focusing Microfluidic Devices
Published on: July 3, 2018
08:31One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes
Published on: September 13, 2018