Related Experiment Video
Updated: Jul 19, 2026

Glycopeptide Capture for Cell Surface Proteomics
Published on: May 9, 2014
Shotgun glycopeptide capture approach coupled with mass spectrometry for comprehensive glycoproteomics
Bingyun Sun1, Jeffrey A Ranish, Angelita G Utleg
1Institute for Systems Biology, Seattle, Washington 98103, USA.
Abstract:
We present a robust and general shotgun glycoproteomics approach to comprehensively profile glycoproteins in complex biological mixtures. In this approach, glycopeptides derived from glycoproteins are enriched by selective capture onto a solid support using hydrazide chemistry followed by enzymatic release of the peptides and subsequent analysis by tandem mass spectrometry. The approach was validated using standard protein mixtures that resulted in a close to 100% capture efficiency. Our capture approach was then applied to microsomal fractions of the cisplatin-resistant ovarian cancer cell line IGROV-1/CP. With a Protein Prophet probability value greater than 0.9, we identified a total of 302 proteins with an average protein identification rate of 136 +/- 19 (n = 4) in a single linear quadrupole ion trap (LTQ) mass spectrometer nano-LC-MS experiment and a selectivity of 91 +/- 1.6% (n = 4) for the N-linked glycoconsensus sequence. Our method has several advantages. 1) Digestion of proteins initially into peptides improves the solubility of large membrane proteins and exposes all of the glycosylation sites to ensure equal accessibility to capture reagents. 2) Capturing glycosylated peptides can effectively reduce sample complexity and at the same time increase the confidence of MS-based protein identifications (more potential peptide identifications per protein). 3) The utility of sodium sulfite as a quencher in our capture approach to replace the solid phase extraction step in an earlier glycoprotein chemical capture approach for removing excess sodium periodate allows the overall capture procedure to be completed in a single vessel. This improvement minimizes sample loss, increases sensitivity, and makes our protocol amenable for high throughput implementation, a feature that is essential for biomarker identification and validation of a large number of clinical samples. 4) The approach is demonstrated here on the analysis of N-linked glycopeptides; however, it can be applied equally well to O-glycoprotein analysis.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis