Related Experiment Video
Updated: Jul 19, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000.
M O Lagravère1, Y Fang, J Carey
1Faculty of Medicine and Dentistry, Dentistry/Pharmacy Centre, University of Alberta, Edmonton, Alberta, Canada T6G 2N8. mlagravere@ualberta.ca
Cone-beam computed tomography (CBCT) can accurately determine material density. A conversion formula was developed to translate Hounsfield Units (HU) from CBCT scans into precise material density measurements.
Area of Science:
- Medical Imaging
- Materials Science
Background:
- Cone-beam computed tomography (CBCT) is increasingly used in various fields.
- Accurate material density determination is crucial for quantitative analysis.
Purpose of the Study:
- To establish a conversion coefficient for Hounsfield Units (HU) to material density (g cm(-3)) using CBCT data.
- To validate the accuracy of CBCT for material density assessment.
Main Methods:
- Six cylindrical models of varying densities were scanned using a NewTom QR-DVT 9000 CBCT scanner.
- Raw CBCT data were processed using Merge eFilm and AMIRA software to extract Hounsfield Units (HU).
- Linear regression analysis was performed to correlate HU with known material densities.
Main Results:
- Software analysis yielded consistent HU values across different platforms (P = 0.846).
- A linear regression model (rho = 0.002H-0.381) demonstrated a strong correlation (R2 = 0.986) between HU and density.
- The model achieved a standard error of 0.064 g cm(-3) for density estimation.
Conclusions:
- CBCT is an effective tool for determining material density.
- The derived conversion coefficient enables accurate density quantification from CBCT Hounsfield Units.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography