Related Experiment Video
Updated: Jul 18, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Magnetic resonance imaging enhancement of normal tissues and tumors using macromolecular Gd-based cascade polymer
Hans-Juergen Raatschen1, Yanjun Fu, David M Shames
1Center for Pharmaceutical and Molecular Imaging, Department of Radiology, University of California, San Francisco, California 94143, USA. robert.brasch@radiology.ucsf.edu
Objectives:
We sought to compare magnetic resonance imaging (MRI) enhancement using 4 novel macromolecular polyethyleneglycol (PEG)-based cascade-polymer gadolinium contrast agents (macromolecular contrast media) in normal soft tissues and a breast cancer model.
Materials And Methods:
Four candidate PEG cascade polymers with effective molecular weights of 74, 82, 106, and 132 kDa, respectively, and T1-relaxivities of 8.1, 9.1, 9.7, and 10.0, respectively (at 2 Tesla and 37 degrees C in HEPES buffer), initially were used to characterize liver and kidney MRI-enhancement patterns in normal Sprague-Dawley rats (n = 4-5 per contrast agent). Kinetic analysis of dynamic MRI enhancement was used in 8 nude rats bearing MDA-MB 435 breast cancers to estimate fractional plasma volume and apparent endothelial leakiness (K) in tumors and muscle.
Results:
Soft-tissue enhancement patterns followed closely the blood enhancement over the course of 30-50 minutes with estimated blood half-lives between 23 and 73 minutes, which varied with effective molecular weights. The 2 smaller compounds yielded measurable leaks in normal muscle [K = 204 and 56 microL/(min.100 cm), respectively], whereas the 2 larger molecules did not leak in muscle [K = 0 microL/(min.100 cm)]; however, MRI-assayed leakiness of tumor vessels with respect to those 2 larger macromolecular contrast media was 68 +/- 27 and 16 +/- 8 microL/(min.100 cm), respectively.
Conclusions:
Two relatively large (effective molecular weight >82 kDa) PEG-based cascade polymer contrast agents were well-suited for MRI quantification of tissue plasma volume and for differentiating leaky cancer microvessels from nonleaky normal vessels.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging