Related Experiment Video
Updated: Jul 18, 2026

Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Ionic basis of ischemia-induced bradycardia in the rabbit sinoatrial node
1Department of Physiology, Texas Tech University Health Sciences Center, 3601 Fourth Street, Lubbock, TX 79430, USA.
Abstract:
To investigate the basis of ischemia-induced bradycardia (<60 beats/min), we isolated pacemaker cells from the rabbit sinoatrial node and exposed them to ischemic-like conditions, including omission of glucose, pH 6.6, and either 5.4 or 10 mM KCl to evaluate the role of increased serum [K]. A perforated-patch technique was employed to test the hypothesis that the arrhythmia is caused by attenuation of inward currents that contribute to the diastolic depolarization. After exposure to "ischemic" Tyrode containing 5.4 mM KCl, the pacemaker cells exhibited 13% slower beat rates and action potentials with 6-mV greater overshoots and 44% longer durations. In contrast, after exposure to "ischemic" Tyrode containing 10 mM KCl, the pacemaker cells exhibited a 7-mV depolarization of the maximum diastolic potential but no significant change in the overshoot. Beat rates were slowed by 43%, and the action potentials were prolonged by 46%. "Ischemic" Tyrode containing 5.4 mM KCl increased L-type Ca current, decreased T-type Ca current and reduced Ni-sensitive inward current tails (presumably Na-Ca exchange current), even after treatment with 40 muM ryanodine to block Ca release from the sarcoplasmic reticulum. "Ischemic" Tyrode containing 10 mM KCl increased hyperpolarization-activated inward current at diastolic potentials and reduced the slowly activating component, but not the rapidly activating component, of delayed rectifier K current. Our results suggest that reductions of inward Na-Ca exchange current and T-type Ca current contribute to "ischemia"-induced "bradycardia" in sinoatrial node pacemaker cells.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism, and...
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias