The HL7 reference information model under scrutiny.

Gunther Schadow1, Charles N Mead, D Mead Walker

  • 1Regenstrief Institute, Indiana University School of Informatics, Indianapolis, IN 46202, USA. gschadow@regenstrief.org

Studies in Health Technology and Informatics
|November 17, 2006
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Decision support from local data: creating adaptive order menus from past clinician behavior.

Journal of biomedical informatics·2013
Same author

Statistical design and analysis of label-free LC-MS proteomic experiments: a case study of coronary artery disease.

Methods in molecular biology (Clifton, N.J.)·2011
Same author

A method to compute treatment suggestions from local order entry data.

AMIA ... Annual Symposium proceedings. AMIA Symposium·2011
Same author

An outline for a vocabulary of nominal properties and examinations--basic and general concepts and associated terms.

Clinical chemistry and laboratory medicine·2010
Same author

Querying the National Drug File Reference Terminology (NDFRT) to assign drugs to decision support categories.

Studies in health technology and informatics·2010
Same author

A recommendation algorithm for automating corollary order generation.

AMIA ... Annual Symposium proceedings. AMIA Symposium·2010
Same journal

The Essential Components and Critical Conditions for Success in a Learning Health System in Oncology.

Studies in health technology and informatics·2026
Same journal

Use of Artificial Intelligence in Screening for Adolescent Idiopathic Scoliosis: A Scoping Review.

Studies in health technology and informatics·2026
Same journal

Movement Related Biomechanics in Adolescent Idiopathic Scoliosis: A Review of Reviews.

Studies in health technology and informatics·2026
Same journal

The Impact of Surgical Correction of Adolescent Idiopathic Scoliosis Using Posterior Spinal Fusion on Selected Radiological Parameters and Respiratory Function.

Studies in health technology and informatics·2026
Same journal

Acute Effect of Physio-logic® Exercises on Muscle Tone and Stiffness in Adolescent Idiopathic Scoliosis Patients: A Preliminary Study.

Studies in health technology and informatics·2026
Same journal

Effects of Integrated Music and Occupational Therapy on Motor and Autonomic Function in Children with Neurogenic Scoliosis.

Studies in health technology and informatics·2026
See all related articles

The Health Level 7 (HL7) Reference Information Model (RIM) harmonizes healthcare messages. This paper, by RIM

Area of Science:

  • Health informatics
  • Healthcare interoperability standards
  • Information modeling in healthcare

Background:

  • The Health Level 7 (HL7) Reference Information Model (RIM) was developed as an object-oriented model to standardize HL7 messages across diverse application domains.
  • Following the success of HL7 version 2, HL7 version 3 and its RIM have garnered significant attention, leading to both praise and criticism in published literature.

Purpose of the Study:

  • To address and respond to the major criticisms leveled against the HL7 RIM in existing publications.
  • To clarify misunderstandings and differing viewpoints contributing to the critique of the HL7 RIM.
  • To foster constructive dialogue for potential improvements to the HL7 standard.

Main Methods:

  • Authors, as chief designers of the RIM, provide a direct response to published criticisms.

Related Experiment Videos

  • Analysis of common criticisms based on misunderstandings and divergent perspectives.
  • Facilitation of dialogue to reconcile differences and promote understanding.
  • Main Results:

    • A significant portion of the criticism against the HL7 RIM stems from misunderstandings and differences in perspective.
    • The authors offer counterpoints and clarifications to address specific critiques.

    Conclusions:

    • The authors aim to advance the discussion surrounding the HL7 RIM by accounting for differing viewpoints.
    • Encouraging effective critique, informed by a clear understanding of the RIM's design principles, can lead to genuine improvements in the standard.