Related Experiment Video
Updated: Jul 18, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Direct determination of chlorophenols in environmental water samples by hollow fiber supported ionic liquid membrane
Jin-Feng Peng1, Jing-Fu Liu, Xia-Lin Hu
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085, China.
Abstract:
The 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) ionic liquid was immobilized in the pores of a polypropylene hollow fiber for hollow fiber-protected liquid-phase microextraction. Analytes including 4-chlorophenol (4-CP), 3-chorophenol (3-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6-trichlorophenol (2,4,6-TCP) were extracted into this ionic liquid membrane, and back extracted into 10microL sodium hydroxide acceptor solution in the lumen of the hollow fiber. Then, the acceptor solution was withdrawn into the high-performance liquid chromatography (HPLC) microsyringe connected to the hollow fiber, and directly injected into the HPLC system for analysis. Some parameters that might affect the extraction efficiency were optimized, and low detection limits (0.5microgL(-1) for 4-CP, 3-CP, DCP and 1.0microgL(-1) for TCP) were obtained. Good repeatability was achieved because of the stability of the hollow fiber-supported ionic liquid membrane. The proposed procedure was applied for direct determination of the four chlorophenols in some real water samples including groundwater, river water, wastewater and tap water. All of the four chlorophenols in these water samples were under the limits of determination, and the recoveries were in the range of 70.0-95.7% at 5microgL(-1) spiked level.
More Related Videos
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Extraction: Advanced Methods