Related Experiment Video
Updated: Jul 18, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Matching the mechanical circulatory support device to the child with heart failure
1Department of Pediatric and Congenital Heart Surgery, Children's Hospital, Cleveland Clinic, Cleveland, Ohio 44195, USA.
Abstract:
A number of mechanical circulatory support devices are currently available for the treatment of children with heart failure refractory to medical therapy. Patient size, the acute versus chronic nature of the heart failure that is present, and the underlying anatomy and physiology define the clinical setting in any given case. Determining which device most effectively meets the specific needs of the clinical setting requires an understanding of the characteristics of each of the available devices. This report describes a graphic representation of the clinical setting in which pediatric heart failure occurs to provide a decision-making framework for the selection of the most appropriate mechanical circulatory support device.
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure VI: Adjunct Therapies
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Heart Failure V: Medical Management