Slip zone and energetics of a large earthquake from the Taiwan Chelungpu-fault Drilling Project

Kuo-Fong Ma1, Hidemi Tanaka, Sheng-Rong Song

  • 1Department of Earth Sciences, National Central University, Chung-Li 32054, Taiwan. fong@earth.ncu.edu.tw

Nature
|November 24, 2006
PubMed

Related Concept Videos

Elastic Strain Energy for Normal Stresses01:22

Elastic Strain Energy for Normal Stresses

Strain energy quantifies the energy stored within a material due to deformation under loading conditions, a fundamental concept in materials science and engineering. The strain energy can be modeled when a material is subjected to axial loading with uniformly distributed stress. In this scenario, the stress experienced by the material is the internal force divided by the cross-sectional area, and the strain induced is directly proportional to this stress through the modulus of elasticity.
If...
726
Elastic Strain Energy for Shearing Stresses01:20

Elastic Strain Energy for Shearing Stresses

As discussed in previous lessons, strain energy in a material is the energy stored when it is elastically deformed, a concept crucial in materials science and mechanical engineering. This energy results from the internal work done against the cohesive forces within the material. When a material undergoes shearing stress and corresponding shearing strain, the strain energy density, which is the energy stored per unit volume, is calculated. Within the elastic limit, where the stress is...
668
Impact Loading01:19

Impact Loading

Impact loading occurs when a moving object collides with a stationary structure, such as a rod with a uniform cross-sectional area fixed at one end. Under these conditions, the rod absorbs the kinetic energy from the striking object, leading to deformation and subsequent stress development. As the rod returns to its original position and reaches maximum stress, the absorbed energy, initially manifested as kinetic energy, transforms entirely into strain energy.
In cases of elastic deformation,...
963
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
601
Microcracking in Concrete01:20

Microcracking in Concrete

Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
614
Dynamic Modulus of Elasticity of Concrete01:16

Dynamic Modulus of Elasticity of Concrete

The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
1.3K