Related Experiment Video
Updated: Jul 18, 2026

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
Sequential alterations of tracheal mechanical properties in the neonatal lamb: effect of mechanical ventilation
Thomas L Miller1, Yan Zhu, Allison R Altman
1Nemours Research Lung Center, Alfred I. duPont Hospital for Children, Wilmington, Delaware 19803, USA. thmiller@nemours.org
Unlabelled:
Alterations in neonatal airway mechanics resulting from ventilatory therapies are implicated in airway collapse and chronic disease. Quantifying the functional impact of mechanical ventilation (MV) on the neonatal airway and elucidating the time course of these changes will support development of protective therapies. The objective of this study was to test the hypothesis that conventional MV would result in decreased static and dynamic elastance of an isolated tracheal segment and thinning of the muscle (trachealis) region of the tracheal wall in a time dependent manner. Tracheal segments were isolated in newborn lambs spontaneously breathing through the distal trachea; segments were MV (n = 7; PIP/PEEP = 35/5 cmH2O; 40 breaths/min) or instrumented, non-ventilated (SHAM; n = 7; PIP/PEEP = 0/0 cmH2O) for 4 hr. At baseline and hourly, tracheal segments were filled with saline, and static pressure-volume curves were constructed as the pressure response to stepwise volume infusions. Then, cross-sectional ultrasound images were captured at 0 cmH2O on SHAM, and at 0 cmH2O, peak inspiratory pressure (PIP) and positive end expiratory pressure (PEEP), on MV tracheae for subsequent dimensional analysis. Tracheal elasticity indices were derived from static pressure-volume data, and during dynamic ventilation using ultrasound images to calculate the stress-strain relationships. Over 4 hr of MV, tracheal internal diameter (ID) increased (14%; P < 0.05). Markers of tracheal mechanical properties indicated a decrease in elasticity under both static (bulk modulus; 28%; P < 0.05) and dynamic (elastic modulus; 282 %; P < 0.05) conditions, indicating a significant alteration in elastic components. No time dependent changes were identified in dimensions or mechanical properties in the SHAM group.
Conclusions:
MV results in dimensional alterations that increased anatomical dead space and reduced static and dynamic elastance of the neonatal trachea.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...