A theoretical framework for evaluating analytical digestion methods for poorly soluble particulate beryllium.

Aleksandr B Stefaniak1, Christopher A Brink, Robert M Dickerson

  • 1National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, WV 26505, USA. AStefaniak@cdc.gov

Analytical and Bioanalytical Chemistry
|November 25, 2006
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Influence of filament loading technique on surrogate active pharmaceutical ingredient particle emissions during material extrusion 3D printing of tablets.

International journal of pharmaceutics·2025
Same author

Assessment of pulmonary toxicity of inhaled polycarbonate 3D printer emissions in rats.

Journal of toxicology and environmental health. Part A·2025
Same author

Perspectives on aerosol inhalability: concepts and applications.

Critical reviews in toxicology·2025
Same author

Absence of lung tumor promotion with reduced tumor size in mice after inhalation of copper welding fumes.

Carcinogenesis·2024
Same author

Carcinogenicity of talc and acrylonitrile.

The Lancet. Oncology·2024
Same author

Pulmonary evaluation of whole-body inhalation exposure of polycarbonate (PC) filament 3D printer emissions in rats.

Journal of toxicology and environmental health. Part A·2024

Accurate atomic spectroscopy requires complete digestion of beryllium particles. Dissolution theory guides digestion strategies, with complete dissolution of the largest particles being key for polydisperse samples.

Area of Science:

  • Environmental Science
  • Analytical Chemistry
  • Materials Science

Background:

  • Accurate atomic spectroscopy relies on complete digestion of all particulate analytes in environmental samples.
  • Beryllium particles, in various chemical forms and sizes, are encountered in occupational settings.
  • Understanding beryllium particle properties is crucial for developing effective digestion procedures.

Purpose of the Study:

  • To investigate the physicochemical properties of beryllium particles from occupational environments.
  • To propose dissolution theory as a framework for developing digestion strategies.
  • To evaluate the sufficiency of digestion procedures for different beryllium particle types.

Main Methods:

  • Investigated physicochemical properties of beryllium particles.

Related Experiment Videos

  • Applied dissolution theory to predict digestion sufficiency.
  • Considered various particle types: monodisperse, polydisperse, and multi-constituent.
  • Main Results:

    • For monodisperse particles, complete dissolution of primary particles is sufficient.
    • For polydisperse particles, complete dissolution of the largest particle is required.
    • Complex samples may need robust treatments and post-digestion filtration.

    Conclusions:

    • Dissolution theory provides a conceptual framework for optimizing beryllium particle digestion.
    • Digestion sufficiency depends on particle characteristics (size, composition, form).
    • Development of particulate reference materials for beryllium is essential for harmonizing analytical methods.