Related Experiment Video
Updated: Jul 18, 2026

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
Published on: February 3, 2014
Aerodynamic and sound intensity measurements in tracheoesophageal voice
Wilko Grolman1, Simone E J Eerenstein, Frédérique M L Tan
1Department of Otorhinolaryngology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. w.grolman@amc.uva.nl
Background:
In laryngectomized patients, tracheoesophageal voice generally provides a better voice quality than esophageal voice. Understanding the aerodynamics of voice production in patients with a voice prosthesis is important for optimizing prosthetic designs and successful voice rehabilitation.
Objectives:
To measure the aerodynamics and sound intensity in tracheoesophageal voice production.
Study Design And Methods:
We built a special setup, which consisted of a Pentium 200 MHz computer with an AD-DA interface card and Labview 4.01 software. In an oral/nasal mask we constructed several mass flow sensors and a microphone. This measured both the oral airflow and the level of sound. For the measurement of endotracheal pressure, which is the driving force behind the airflow, we used a transducer which was connected to the tracheostoma. The endoesophageal pressure was measured at the level of the prosthesis in the esophagus by a Mikrotip transducer. Using this we could determine how much the voice prosthesis contributes to the overall pressure drop of the phonatory tract. Furthermore, the average airflow rate as a function of the sound pressure levels could be determined.
Results:
In our population, 6 out of 7 patients showed a positive relationship between trans-source airflow and generated sound intensity. We compared our prosthesis pressure drop values with in vitro data and found that there are some differences, possibly due to difference in age of the prosthesis and physiological circumstances in vivo. The overall contribution of the voice prosthesis to the airway resistance depends on the level of phonation and the type of device. In our patient group it is apparent that the pharyngoesophageal (PE) segment has the greatest share of the total pressure drop, especially at higher airflow rates. We measured a 27% pressure drop in airflow over the voice prosthesis. Different tracheostoma occlusion methods did not have any effect on the aerodynamics and sound intensity. One patient that had had a jejunal graft for reconstruction showed, not unexpectedly, extremely different aerodynamic values. We were unable to define optimal airflow rates or optimal resistance values for sound production in the PE segment.
Conclusion:
The aerodynamic characteristics of voice production in laryngectomized patients with voice prostheses are determined by both prosthetic factors and PE segment tissue factors. In our patient group the PE segment is responsible for the greatest pressure drop. We found no significant difference in pressure drop and sound intensity for different tracheostoma occlusion methods.
Related Concept Videos
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive and...
Tracheostomy Suctioning II: Procedure

