Assessing children's heart sounds at a distance with digital recordings
John P Finley1, Andrew E Warren, Geoffrey P Sharratt
1IWK Children's Heart Centre, 5850/5950 University Ave, Halifax, NS, Canada B3K6R8. john.finley@iwk.nshealth.ca
Objective:
The objective of this study was to assess whether computer-stored digital sound recordings can be used to distinguish innocent from pathologic systolic murmurs.
Methods:
Recordings of 55 children aged 1 month to 19 years were made remotely with the use of a digital stethoscope and were e-mailed to a computer in our center for later assessment. Eight-second recordings were made by a physician in 2 to 4 locations on the chest. Three cardiologists who were blinded to the diagnosis reviewed the recordings independently using stethophones to assess the splitting of the second heart sound and whether murmurs were innocent or pathologic. Diagnoses were confirmed with echocardiography.
Results:
Seventeen children had innocent murmurs and 38 had pathologic murmurs. For the 3 cardiologists, sensitivity was 0.87 to 1.0, specificity was 0.82 to 0.88, negative predictive value was 0.75 to 1.0, and positive predictive value was 0.93 to 0.95. Assessment of splitting of second heart sound was highly accurate.
Conclusions:
Digital recordings of children's heart sounds allow reliable differentiation between innocent and pathologic murmurs. Use of this technology may allow remote diagnosis of childhood murmurs and avoid the expense and stress of travel to pediatric cardiology centers for some children. Cardiologists who use recordings should assess their diagnostic accuracy before clinical application.
More Related Videos
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...