Related Experiment Video
Updated: Jul 18, 2026

Preparation and Application of a New Bacterial Biosensor for the Presumptive Detection of Gunshot Residue
Published on: May 9, 2019
Temporary threshold shift due to recreational firearm use
1Department of Otolaryngology and Head and Neck Surgery, St Mary's Hospital, London, UK. urmibapat@yahoo.com
Recreational firearm use, even with ear protection, can cause temporary threshold shifts in hearing. This study found significant hearing changes in most participants after shooting a .22 caliber rifle.
Area of Science:
- Audiology
- Occupational Health
- Environmental Health
Background:
- Firearm use is a common recreational activity.
- Exposure to impulse noise from firearms can potentially cause hearing damage.
- Understanding the effects of recreational firearm noise on hearing is crucial for public health.
Purpose of the Study:
- To investigate the occurrence of temporary threshold shift (TTS) after recreational firearm use.
- To evaluate the impact of impulse noise from a .22 caliber rifle on hearing sensitivity.
Main Methods:
- An observational study involving 25 subjects was conducted in an indoor rifle range.
- Hearing thresholds were measured before and after firing five rounds of a .22 caliber rifle over 10 minutes.
- Statistically significant threshold shift was defined as 5 dB, and clinically significant as 10 dB.
Main Results:
- A statistically significant threshold shift was observed in 24 subjects, and a clinically significant shift in 12 subjects.
- Subjects with prior industrial noise exposure exhibited threshold shifts at more frequencies.
- No significant difference in hearing changes was noted between the left and right ears.
Conclusions:
- This study suggests that recreational firearm use can lead to temporary threshold shifts, even with ear protection.
- The findings indicate that impulse noise from firearms warrants attention regarding hearing conservation.
- Further research is needed to draw definitive conclusions on the long-term effects and optimal protection strategies.
Related Concept Videos
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
Dose Response Curve: Conventional Versus Nonmonotonic
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
The Anchoring-and-Adjustment Heuristic
Integration of Synaptic Events
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or calcium...

