Related Experiment Video
Updated: Jul 18, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
[Are blood glucose analyzers safe? Experiences of the BfArM based on all notifications received until end of 2005]
1Bundesinstitut für Arzneimittel und Medizinprodukte, Bonn, Germany. r.siekmeier@bfarm.de
Abstract:
Since implementation of the Directive 98/79/EC of the European Parliament and of the Council on in vitro Diagnostic Medical Devices (IVD Directive), issues and field corrective actions on in vitro diagnostic medical devices (IVDMD) have to be reported to the national competent authorities. In Germany these are the BfArM and the Paul Ehrlich Institute; the latter is responsible for Annex II products used for immune hematology, tissue typing and infectiology testing. Between the beginning of 1999 and the end of 2005 BfArM received n=653 notifications on IVDMD. From these n=128 concerned analyzers and sensors (test strips) for self monitoring of blood glucose. A similar quantity of cases was reported by users and manufacturers (44.5%). In n=31 of these cases a product defect was not confirmed after the investigation of the products by the manufacturers. Product failures were confirmed in n=35 cases. The remaining cases were caused by user errors (n=29) or the data were inconclusive (n=33), predominantly because the products were not or only partly available for investigation by the manufacturers. In those cases where product failure had been verified n=24 affected the sensors (test strips) and n=11 the analyzers. Corrective actions were performed by the manufacturers in n=34 cases. From these n=27 were cases in which a product failure had been detected. However, in n=7 cases the investigations of the manufacturers were followed by preventive corrective actions because the manufacturers became aware of potential causes of future product failures. The obtained results and experiences since 1999 show that the governmental system for post-marketing surveillance of products for self testing of blood glucose is an established tool to ensure product safety. Regarding the proportion of notifications concerning these over the counter (OTC) products, it becomes obvious that they are a focus for action for the competent surveillance authorities.
Related Concept Videos
Hypoglycemia and Glucagon
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Hypoglycemia