On-line coupling of dynamic microwave-assisted extraction with high-performance liquid chromatography for determination of andrographolide and dehydroandrographolide in Andrographis paniculata Nees
Related Experiment Video
Updated: Jul 18, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Ligang Chen1, Haiyan Jin, Lan Ding
1College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012, China.
Abstract:
A novel technique based on dynamic microwave-assisted extraction (DMAE) coupled on-line with high-performance liquid chromatography (HPLC) through a flow injection interface has been developed for determination of andrographolide and dehydroandrographolide in Andrographis paniculata Nees. A TM(010) microwave resonance cavity built in the laboratory was applied to concentrating the microwave energy. An extraction vessel was placed in microwave irradiation zone. The extraction was performed in a recirculating system. When a number of extraction cycles were completed, the fractional extract (20muL) was driven to the analytical column by 65% aqueous methanol and was measured by diode array detector (DAD) at 225nm. The optimized extraction conditions are follows: extraction solvent 60% aqueous methanol; microwave forward power 80W; extraction time 6min; extraction solvent flow-rate 1.0mLmin(-1). The detection and quantification limits obtained are 0.5 and 1.7microgmL(-1) for andrographolide and 0.6 and 1.9microgmL(-1) for dehydroandrographolide, respectively. The within-day and between-day precision (RSD) are 2.1% and 3.7% for andrographolide and 1.7% and 4.1% for dehydroandrographolide, respectively. Mean recoveries for andrographolide and dehydroandrographolide are 97.7% and 98.7%, respectively. Compared with ultrasonic extraction used in the Chinese pharmacopoeia, the proposed method was demonstrated to obtain higher extraction yield in a shorter time. In addition, only small quantities of solvent (5mL) and sample (10mg) were required.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:10An Efficient and Rapid HPLC-QQQ-MS Method for the Quantitation of Tropane Alkaloids in Medicinal Plants
Published on: June 12, 2026
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: