Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Characterization of capillary-channeled polymer fiber stationary phases for high-performance liquid chromatography
Dwella M Nelson1, R Kenneth Marcus
1Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, South Carolina 29634, USA.
Abstract:
Capillary-channeled polymer (C-CP) fibers are investigated as reversed-phase (RP) stationary phases for high-performance liquid chromatography of proteins. A comparative analysis of column characteristics for polypropylene and poly(ethylene terephthalate) C-CP fiber columns and a conventional packed-bed (C4-derivatized silica) column has been undertaken. Five proteins (ribonuclease A, cytochrome c, lysozyme, myoglobin, bovine serum albumin) were used to investigate the separation characteristics under typical RP gradient conditions. Column performance was compared under standard (identical) and optimized RP chromatographic conditions. The gradient compositions utilized with the C-CP fiber columns are similar to those used with conventional columns, employing flow rates in the 1-6 mL/min range and gradient rates of approximately 1%/min. The packed-bed column was operated as prescribed by the column manufacturer. The retention factor (k'), separation factor (alpha), resolution (Rs), asymmetry factor (As), elution order, and peak capacity values of a four protein separations performed on the C-CP fiber columns are compared to the same separation on the C4 column. One unique feature observed here is the lessening of the percentage of organic modifier necessary to elute the proteins from the fiber phases with increased linear velocity. The potential contribution of the different stationary phases to protein denaturation was evaluated through a spectrophotometric enzymatic activity assay. The repeatability of retention times under both sets of conditions for six consecutive injections of lysozyme on each C-CP fiber column is < or =1.5% RSD. The column-to-column reproducibility of retention times for three columns of each fiber type is also < or =1.5% RSD. The overall performance of the C-CP fiber columns was comparable to the conventional column used in these studies. Basic characteristics demonstrated here suggested further developments in the areas of ultrafast protein separations and preparative-scale protein chromatography.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...