Related Experiment Video
Updated: Jul 18, 2026

Gastric Point of Care Ultrasound in Adults: Image Acquisition and Interpretation
Published on: September 22, 2023
Single photon emission computed tomography for gastric volume assessment: a method with observer-defined regions of
Jan L Madsen1, Stefan Fuglsang, Jesper Graff
1Department of Clinical Physiology and Nuclear Medicine, Hvidovre Hospital, Hvidovre, Denmark. jan.lysgaard.madsen@hh.hosp.dk
Aim:
Single photon emission computed tomography (SPECT) imaging allows non-invasive measurement of gastric volume. In previous studies, the processing of the SPECT data involved global threshold algorithms that do not take into account the non-uniform distribution of radioactivity in the gastric wall. The aim of this study was to develop a simple alternative method based on observer-defined regions of interest.
Methods:
A phantom study was performed to standardize volume calculations from SPECT derived cross-sectional areas. In 12 healthy volunteers, the principle was then used to determine gastric volume before and after a 600 ml liquid meal. Furthermore, gastric emptying of the meal was followed with planar scintigraphy.
Results:
The median volume of the stomach was 86 ml (range 62-130 ml) at baseline, 642 ml (536-748 ml) immediately after the meal, and 370 ml (221-481 ml) 1 h after the meal. The coefficient of variation for the calculations was 9%, 2% and 4%, respectively. The median increase in gastric volume was 562 ml (501-628 ml) immediately after the meal and 294 ml (159-370 ml) after 1 h. Gastric retention of the meal was 68% (50-73%) after 0.5 h and 51% (39-57%) after 1 h.
Conclusions:
The present manual technique may be a reliable alternative to the automated SPECT methods for assessing gastric volume. The liquid meal that was used in our study did not seem to cause an increase in gastric volume that differed from the volume of the meal.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

