82Rb and [15O]H2O myocardial perfusion PET imaging: a prospective head to head comparison
Martin Krakauer1, Afefah Ismail1, Ulrik Talleruphuus1
1Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark.
Background:
82Rb PET and [15O]H2O PET are both validated tracers for myocardical perfusion imaging but have not previously been compared clinically. During our site's transition from 82Rb to [15O]H2O PET, we performed a head-to-head comparison in a mixed population with suspected ischemic heart disease.
Methods:
A total of 37 patients referred for perfusion imaging due to suspicion of coronary stenosis were examined with both 82Rb and [15O]H2O PET on the same day in rest and during adenosine-induced stress. The exams were rated by two blinded readers as normal, regional ischemia, globally reduced myocardial perfusion, or myocardial scarring. For [15O]H2O PET, regional ischemia was defined as two neighboring segments with average stress perfusion ≤ 2.3 mL/(min·g). Further, we evaluated a total perfusion deficit (TPD) of ≥ 10% as a more conservative marker of ischemia.
Results:
[15O]H2O PET identified more patients with regional ischemia: 17(46%) vs 9(24%), agreement: 59% corresponding to a Cohen's kappa of .31 [95%CI .08-.53], (P < .001). Using the more conservative TPD ≥ 10%, the agreement increased to 86% corresponding to a kappa of .62 [95%CI .33-.92], (P = .001). For the subgroup of patients with no known heart disease (n = 18), the agreement was 94%. Interrater agreement was 95% corresponding to a kappa of .89 [95%CI .74-1.00] (P < .001).
Conclusions:
In clinical transition from 82Rb to [15O]H2O PET, it is important to take into account the higher frequency of patients with regional ischemia detected by [15O]H2O PET.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...