Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Characterization of liver lesions by real-time contrast-enhanced ultrasonography
Natascia Celli1, Stefano Gaiani, Fabio Piscaglia
1Division of Internal Medicine, Department of Internal Medicine and Gastroenterology, Alma Mater Studiorum, University of Bologna, Italy. naticel@yahoo.it
Objective:
The aim of this study was to identify the most common patterns of various common liver lesions at real-time contrast-enhanced ultrasonography with second-generation contrast agents and their role in the differentiation of malignant from benign lesions.
Patients And Methods:
The enhancement pattern in the arterial phase and its modifications in subsequent portal and sinusoidal phases were separately evaluated in (i) 171 liver lesions detected at conventional ultrasonography in 125 noncirrhotic patients (87 metastases, six cholangiocellular carcinoma, 38 focal nodular hyperplasia, 30 hemangiomas, seven focal fatty sparing/changes, two hepatocellular adenomas and one hepatocellular carcinoma) and (ii) 75 lesions detected in 67 cirrhotic patients (66 hepatocellular carcinoma and nine dysplastic nodules). The final diagnosis was made by contrast-enhanced helical computed tomography and/or magnetic resonance imaging or by ultrasonography-guided biopsy when the diagnosis was equivocal at conventional imaging techniques (45 lesions).
Results:
In noncirrhotic patients, the hypoechoic pattern in portal and sinusoidal phase (rapid washout) or the markedly hypoechoic or anechoic pattern in sinusoidal phase (marked late washout) showed a sensitivity, specificity and accuracy of 96.8, 100 and 98.2% for the diagnosis of malignancy. In cirrhotic patients, early arterial enhancement showed a sensitivity of 93.9% for the diagnosis of malignancy, with a specificity as low as 55.5% given the presence of arterial enhancement in 5/9 nodules resulted dysplastic at histological analysis.
Conclusion:
Real-time contrast-enhanced ultrasonography provides sensitive and specific criteria for the differential diagnosis between benign and malignant liver lesions, and in most cases it may replace more expensive and invasive imaging techniques.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Liver Histology
Hepatocytes perform a variety of essential functions. They secrete...
Imaging Studies II: Ultrasonography
Gross Anatomy of the Liver
Located under the diaphragm, the liver is almost entirely ensconced within the rib cage, providing it with substantial protection. Except for the superior most bare area, the liver's surface is covered...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...