Related Experiment Video
Updated: Jul 17, 2026

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial
1University of Iowa Roy J. and Lucille A. Carver College of Medicine, Iowa City, Iowa 52242, USA. javier-campos@uiowa.edu
Purpose Of Review:
This review is a clinical comparison between double-lumen endotracheal tubes and bronchial blockers to determine which device is considered the best for lung isolation.
Recent Findings:
Double-lumen endotracheal tubes and bronchial blockers have been found to be clinically equivalent in terms of performance in providing lung collapse for patients with normal airways. In the last five years, however, numerous reports have indicated a preference for the use of bronchial blockers in patients with airway abnormalities. For nonthoracic anesthesiologists who have limited experience in thoracic anesthesia cases, none of the devices (double-lumen tubes or bronchial blockers) have been shown to provide any advantage while in use due to a high incidence of unrecognized malpositions. Overall, each device provides advantages depending upon the case, such as absolute lung separation with a double-lumen endotracheal tube or the use of a bronchial blocker in a difficult airway for a patient requiring lung isolation.
Summary:
Double-lumen endotracheal tubes and bronchial blockers should be part of the armamentarium of every anesthesiologist involved in lung isolation techniques and every device should be tailored to specific case needs.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Inhaled Medications
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...