Related Experiment Video
Updated: Jul 17, 2026

Measuring Nucleotide Binding to Intact, Functional Membrane Proteins in Real Time
Published on: March 11, 2021
Slow conformational changes of the voltage sensor during the mode shift in hyperpolarization-activated
Andrew Bruening-Wright1, H Peter Larsson
1Neurological Sciences Institute, Oregon Health and Science University, Beaverton, Oregon 97006, USA.
Abstract:
Hyperpolarization-activated cyclic-nucleotide-gated (HCN) channels are activated by hyperpolarizations that cause inward movements of the positive charges in the fourth transmembrane domain (S4), which triggers channel opening. If HCN channels are held open for prolonged times (>50 ms), HCN channels undergo a mode shift, which in sea urchin (spHCN) channels induces a >50 mV shift in the midpoint of activation. The mechanism underlying the mode shift is unknown. The mode shift could be attributable to conformational changes in the pore domain that stabilize the open state of the channel, which would indirectly shift the voltage dependence of the channel, or attributable to conformational changes in the voltage-sensing domain that stabilize the inward position of S4, thereby directly shifting the voltage dependence of the channel. We used voltage-clamp fluorometry to detect S4 movements and to correlate S4 movements to the different activation steps in spHCN channels. We here show that fluorophores attached to S4 report on fluorescence changes during the mode shift, demonstrating that the mode shift is not simply attributable to a stabilization of the pore domain but that S4 undergoes conformational changes during the mode shift. We propose a model in which the mode shift is attributable to a slow, lateral movement in S4 that is triggered by the initial S4 gating-charge movement and channel opening. The mode shift gives rise to a short-term, activity-dependent memory in HCN channels, which has been shown previously to be important for the stable rhythmic firing of pacemaking neurons and could significantly affect synaptic integration.
More Related Videos
09:54Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers
Published on: November 19, 2015
10:59Use of Label-free Optical Biosensors to Detect Modulation of Potassium Channels by G-protein Coupled Receptors
Published on: February 10, 2014
Related Concept Videos
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Ligand-Gated Ion Channel Receptor: Gating Mechanism
G-Protein Gated Ion Channels
Sensory organs,...
Mechanically-gated Ion Channels
Mechanically-gated Ion Channels