Related Experiment Video
Updated: Jul 17, 2026

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Immediate hemodynamic effect of the additional use of the SCD EXPRESS Compression System in patients with venous
E Kalodiki1, M Ellis, S K Kakkos
1Imperial College, London, UK. e.kalodiki@imperial.ac.uk
Objectives:
To test the hypothesis that the SCD EXPRESS intermittent pneumatic compression applied in combination with a four-layer bandage in patients with venous ulcers increases popliteal vein volume flow and velocity.
Design:
Twenty limbs of 18 patients with venous leg ulcers were studied, median age 76 years. The Total Volume Flow (TVF) and the Peak Systolic Velocity (PSV) were recorded in the popliteal vein using duplex ultrasonography. Measurements were made (i) without bandage, (ii) with four layer bandage and (iii) following the application of the SCD Compression System on top of a four-layer bandage for at least 15 minutes.
Results:
The median VCSS was 17 (range, 12-22) while the median VSDS for reflux was 4.5 (range, 1-7.5). The median TVF was 71 mL/min (inter-quartile range 57-101) without bandage, 112 (IQR 89-148) with four-layer bandage and 291 (IQR 241-392) with the addition of the SCD System (P<.001, Wilcoxon signed ranks test). The median PSV was 8.4 cm/sec (IQR 6.8-14) without bandage, 13 (9.0-19) with four-layer bandage and 27 (21-31) with the addition of the SCD System (P<.001, Wilcoxon signed ranks test). Both TVF and PSV increased slightly with the addition of the four-layer bandage. However, with the addition of the SCD System these parameters increased three fold.
Conclusions:
The SCD EXPRESS Compression System accelerates venous flow in the legs of patients with venous ulcers already treated with a four-layer bandage. The combination of four-layer compression with the SCD System on healing venous ulcers needs to be tested by a clinical effectiveness study.
Related Concept Videos
Venous Thrombosis IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Artery Disease V: Postoperative Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis III: Interprofessional Care