Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Price of isotropy in multidetector CT
Neal C Dalrymple1, Srinivasa R Prasad, Fadi M El-Merhi
1Department of Radiology, University of Texas Health Science Center at San Antonio, Mail Code 7800, 7703 Floyd Curl Dr, San Antonio, TX 78229-3900, USA. dalrymplen@uthscsa.edu
Abstract:
Recent advances in multidetector computed tomography (CT) have made isotropic data acquisition feasible for nearly every application. The benefits of routine use of isotropic data for image display and interpretation have been described in the literature and at educational conferences. However, there is usually a trade-off in the form of an increased radiation dose to the patient. The parameters that affect the radiation dose vary considerably in accordance with the CT scanner design, and those variations determine the cost in dose increase relative to the voxel size. The detector configuration and beam collimation (narrow or wide) used for a particular acquisition also affect the voxel size and the relationship between spatial resolution and the radiation dose. By closely comparing the quality of multidetector CT images obtained with different detector configurations on scanners with four, 16, 40, and 64 channels and the estimated radiation exposure incurred with each option, radiologists may achieve an understanding of the relationship between radiation dose and voxel size. This understanding, in turn, may help balance the need for diagnostic image quality against the concern for patient safety.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET