Reproducibility of physiological track-and-trigger warning systems for identifying at-risk patients on the ward
Christian P Subbe1, Haiyan Gao, David A Harrison
1Department of Medicine, Wrexham Maelor Hospital, Wrexham LL13 4TX, UK.
Objective:
Physiological track-and-trigger warning systems are used to identify patients on acute wards at risk of deterioration, as early as possible. The objective of this study was to assess the inter-rater and intra-rater reliability of the physiological measurements, aggregate scores and triggering events of three such systems.
Design:
Prospective cohort study.
Setting:
General medical and surgical wards in one non-university acute hospital.
Patients And Participants:
Unselected ward patients: 114 patients in the inter-rater study and 45 patients in the intra-rater study were examined by four raters.
Measurements And Results:
Physiological observations obtained at the bedside were evaluated using three systems: the medical emergency team call-out criteria (MET); the modified early warning score (MEWS); and the assessment score of sick-patient identification and step-up in treatment (ASSIST). Inter-rater and intra-rater reliability were assessed by intra-class correlation coefficients, kappa statistics and percentage agreement. There was fair to moderate agreement on most physiological parameters, and fair agreement on the scores, but better levels of agreement on triggers. Reliability was partially a function of simplicity: MET achieved a higher percentage of agreement than ASSIST, and ASSIST higher than MEWS. Intra-rater reliability was better then inter-rater reliability. Using corrected calculations improved the level of inter-rater agreement but not intra-rater agreement.
Conclusion:
There was significant variation in the reproducibility of different track-and-trigger warning systems. The systems examined showed better levels of agreement on triggers than on aggregate scores. Simpler systems had better reliability. Inter-rater agreement might improve by using electronic calculations of scores.
More Related Videos
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
09:42Using Continuous Data Tracking Technology to Study Exercise Adherence in Pulmonary Rehabilitation
Published on: November 8, 2013
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Errors occurring during blood pressure monitoring
Several factors...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.