Related Experiment Video
Updated: Jul 17, 2026

Noninvasive Sampling of Mucosal Lining Fluid for the Quantification of In Vivo Upper Airway Immune-mediator Levels
Published on: August 7, 2017
Simultaneous in vivo measurements of intranasal air and mucosal temperature
Kerstin Wiesmiller1, Tilman Keck, Richard Leiacker
1Department of Otorhinolaryngology, University of Ulm, Frauensteige 12, 89075, Ulm, Germany. kerstin.wiesmiller@uniklinik-ulm.de
Abstract:
Nasal cavity volume and blood temperature along the nasal airways, reflecting the mucosal temperature, are considered to be the most important predictors of nasal air conditioning. The purpose of this study was to simultaneously in vivo measure intranasal air as well as mucosal temperature for the first time. Fifteen healthy subjects were enrolled into the study. Two combined miniaturized thermocouples were used for simultaneous recording of intranasal air and mucosal temperature within the anterior turbinate area close to the head of the middle turbinate without interruption of nasal breathing. The highest air and mucosal temperature values were detected at the end of expiration, the lowest values at the end of inspiration. The difference was statistically significant (P < 0.05). The mean mucosal temperature ranged from 30.2 +/- 0.9 to 32.2 +/- 0.8 degrees C. The mean air temperature ranged from 28.5 +/- 1.2 to 34.1 +/- 0.7 degrees C. The mean differences between air and mucosal temperature were 1.7 +/- 0.5 degrees C after inspiration and 1.9 +/- 0.7 degrees C after expiration. Simultaneous measurements of intranasal air and mucosal temperature are practicable. The detected temperature gradient between air and mucosa confirm a relevant heat exchange during inspiration and expiration. This gradient between air and mucosa is obligatory for heat and water exchange to ensure adequate nasal air conditioning.
More Related Videos
11:54Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
Published on: January 21, 2018
09:58A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 13, 2010
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...