A new method using coherence to obtain the model order in the evaluation of partial directed coherence

R A Thuraisingham1

  • 1ranjit@optusnet.com.au

Related Concept Videos

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
Per-Unit Sequence Models01:26

Per-Unit Sequence Models

An ideal Y-Y transformer, grounded through neutral impedances, displays per-unit sequence networks akin to those of a single-phase ideal transformer when subjected to balanced positive- or negative-sequence currents. These currents do not produce neutral currents, and their associated voltage drops.
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...
Typical Model Studies01:30

Typical Model Studies

Fluid mechanics model studies often utilize scaled-down systems to predict fluid behavior in full-scale environments, such as river flows, dam spillways, and structures interacting with open surfaces. Maintaining Froude number similarity in river models is crucial, as it replicates surface flow features like wave patterns and velocities.
Extraction: Partition and Distribution Coefficients01:14

Extraction: Partition and Distribution Coefficients

The distribution law or Nernst's distribution law is the law that governs the distribution of a solute between two immiscible solvents. This law, also known as the partition law, states that if a solute is added to the mixture of two immiscible solvents at a constant temperature, the solute is distributed between the two solvents in such a way that the ratio of solute concentrations in the solvents remains constant at equilibrium.
For extracting a solute from an aqueous phase into an organic...
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...