On the precision of calculated solvent-accessible surface areas.
Marian Novotny1, Marvin Seibert, Gerard J Kleywegt
1Department of Cell and Molecular Biology, Uppsala University, Biomedical Centre, Box 596, SE-751 24, Uppsala, Sweden.
Protein structure models have limited accuracy, affecting calculated solvent-accessible surface areas (ASA). This study reveals ASA precision is often within 50-100 A², suggesting reporting higher precision is unrealistic.
Area of Science:
- Structural biology
- Biophysics
- Computational chemistry
Background:
- Protein structures are inherently dynamic.
- Experimental methods like X-ray crystallography, electron microscopy (EM), and nuclear magnetic resonance (NMR) yield models with inherent inaccuracies.
- These structural limitations impact the precision of calculated molecular properties, such as solvent-accessible surface areas (ASA).
Purpose of the Study:
- To investigate the precision of calculated solvent-accessible surface areas (ASA).
- To quantify the impact of atomic coordinate variations on ASA values.
- To establish realistic precision limits for reporting ASA in structural biology.
Main Methods:
- Analysis of selected protein structures of varying sizes.
- Introduction of random shifts to atomic coordinates to assess ASA variability.
- Calculation of ASA for multiple structures within the Protein Data Bank (PDB) ensembles.
- Examination of a molecular dynamics (MD) trajectory for lysozyme.
- Comparison of ASA values computed using different software packages.
Main Results:
- Standard deviations in ASA calculations ranged from approximately 10 to 80 A² due to coordinate variations.
- A set of 69 hen egg-white lysozyme structures showed a standard deviation of 81 A² for ASA.
- ASA values exhibited a range of over 800 A² during molecular dynamics simulations.
- Different programs yielded ASA values with a spread of nearly 600 A² for a small protein.
- No correlation was found between ASA precision and resolution or temperature factors.
Conclusions:
- Reporting ASA values with precision better than 10 A² is generally unrealistic.
- A prudent precision for reporting ASA values is between 50-100 A².
- The precision of buried surface area calculations for protein complexes also warrants consideration.
Related Concept Videos
Calculating Equilibrium Concentrations
A more...
Surface Area Calculations
The Small x Assumption
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Factors Affecting Dissolution: Particle Size and Effective Surface Area