Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device
Adam R Travis1, Guruprasad A Giridharan, George M Pantalos
1Cardiovascular Innovation Institute, University of Louisville, Louisville, Ky 40202, USA.
The Journal of Thoracic and Cardiovascular Surgery
|January 30, 2007
Summary
Pulsatile support for left ventricular assist devices (LVADs) better restores vascular pulsatility and energy compared to continuous-flow LVADs. Device selection impacts vascular impedance and compliance, potentially influencing patient outcomes.
Area of Science:
- Cardiovascular Physiology
- Medical Device Engineering
Background:
- Heart failure significantly alters ventricular function and vascular hemodynamics.
- Left ventricular assist devices (LVADs) are crucial for end-stage heart failure management.
- Understanding the hemodynamic effects of different LVAD flow types is vital.
Purpose of the Study:
- To compare vascular pulsatility indices between normal ventricular function and heart failure patients.
- To investigate hemodynamic differences between continuous-flow and pulsatile-flow LVADs.
- To assess the impact of LVAD type on vascular input impedance and pulsatility.
Main Methods:
- Studied 8 normal ventricular function patients and 22 heart failure patients.
- Utilized high-fidelity pressure catheters and transit-time flow probes for hemodynamic data acquisition.
- Calculated vascular input impedance, energy-equivalent pressure, and surplus hemodynamic energy across varying device flow rates.
Main Results:
- Pulsatile support restored surplus hemodynamic energy close to normal values, while continuous support drastically reduced it.
- Continuous support at high levels diminished surplus energy by 97%, whereas pulsatile support augmented it by 49%.
- Pulsatile support reduced vascular impedance and maintained vascular compliance, unlike continuous support which increased impedance and indicated stiffening.
Conclusions:
- LVAD type and flow rate significantly influence vascular pulsatility and input impedance.
- These hemodynamic changes may have implications for clinical outcomes in LVAD patients.
- Pulsatile LVAD support appears more favorable for maintaining vascular health compared to continuous-flow support.
Related Concept Videos
Pulse
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
The pulse serves as a clinical indicator...
Pulse rhythm
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...