Related Experiment Video
Updated: Jul 17, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
The magic angle effect: a source of artifact, determinant of image contrast, and technique for imaging
Mark Bydder1, Andres Rahal, Gary D Fullerton
1Department of Radiology, University of California, San Diego 92103, USA.
Abstract:
This review provides a formalism for understanding magic angle effects in clinical studies. It involves consideration of the fiber-to-field angle for linear structures such as tendons, ligaments, and peripheral nerves, disc-like and circular structures such as menisci and labra, as well as complex three-dimensional structures. There may be one or more fiber types with different orientations within each of these tissues. The orientation of these fibers to B(0) is crucial in determining their magic angle effect. Tissues may show a variety of appearances depending on their baseline T2, as well as the increase in T2 produced by the magic angle effect. The appearances are affected by TE, which affects both the general tissue signal level and the change in signal produced by the magic angle effect, fiber-to-slice orientation, and partial volume effects. Deliberate positioning of structures and tissues at particular orientations to B(0) can be used to increase the signal from tissues such as tendons and ligaments and so allow them to be imaged with conventional sequences. The technique can also be used to produce contrast between tissues with fibers that have different orientations to B(0).
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Magnetic Resonance Imaging
X-ray Imaging
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Overview of Microscopy Techniques

