Continuous blood pressure monitoring utilizing a CMOS tactile sensor
T Salo1, K-U Kirstein, J Sedivý
1Physical Electronics Laboratory, Swiss Federal Institute of Technology, Zurich, Switzerland.
Abstract:
A novel tactile device based on a monolithically integrated sensor chip is presented for external blood pressure measurement. It uses a tonometric principle, thus allowing for continuous monitoring of the blood pressure without the need for an invasive catheter. On the chip, the deflection of membranes in an array is sensed capacitively and read out using a SigmaDelta-modulator. The membrane array and the modulator are fabricated on a single chip using an industrial CMOS (complementary metal oxide semiconductor) technology combined with post-process micromachining to achieve small and portable devices with low power consumption. The tested device is operated at a conversion rate of 1 kilosamples per second and is pressure biased to a 2000 hPa (1500 mmHg) reference point. The power consumption of the sensor chip is 11.5 mW with signal-to-noise ratio better than 72 dB. During testing a pressure resolution of approximately 8 hPa (6 mmHg) for one digit at the output of the SigmaDelta-modulator is achieved over the range of interest continuous blood pressure monitoring using this CMOS-based tactile device is successfully demonstrated. The characteristic features of a blood pressure waveform are clearly recognizable from the acquired data.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: