Related Experiment Video
Updated: Jul 17, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Development of dosimetry using detectors of diagnostic digital radiography systems
Eiji Ariga1, Shigeki Ito, Shizuhiko Deji
1Graduate School of Environmental Studies, Nagoya University and Nagoya Daini Red Cross Hospital, 466-8650, Nagoya, Japan.
Abstract:
Dosimetry using an imaging plate (IP) of computed radiography (CR) systems was developed for quality control of output of the x-ray equipment. Sensitivity index, or the S number, of the CR systems was used for estimating exposure dose under the routine condition: exposure dose from 1.0 to 1.0 x 10(2) microC kg(-1), tube voltages from 50 to 120 kV, and added filtration from 0 to 4.0 mm Al. The IP was calibrated by using a 6 cc ionization chamber having traceability to the National Standard Ionization Chamber. The uncertainty concerning the fading effect was suppressed less than 1.9% by reading the latent image 4 min+/-5 s after irradiation at the room temperature 25.9+/-1.0 degrees C. The S number decreased linearly on the logarithmic graph regardless of the beam quality as exposure dose increased. The relationship between the exposure dose (E) and the S number was fitted by the equation E=a' X S(-b). The coefficient a' decreased when the added filtration and the tube voltage were increased. The coefficient b was 0.977+/-0.007 in all beam qualities. The dosimetry using the IP and the equation can estimate the exposure dose in a range from 9.0 x 10(-2) to 5.0 microC kg(-1) within an uncertainty of +/-5% required by the Japanese Industry Standard. This dose range partially included the doses under routine condition. The doses between 1.0 and 1.0 x 10(2) microC kg(-1) under the routine condition can be shifted to the 5% region by using an absorber. The IP dosimetry is applicable to the quality control of the CR systems.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Related Concept Videos
Determination of Crystal Structures
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Biological Effects of Radiation