A Multi Parameters Wearable Telemetric System for Cardio-Pulmonary Fitness of e-Health
Related Experiment Video
Updated: Jul 17, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Tsung-Che Chou1, Nan-Fu Chiu, Fang-Ren Liao
1Institute of Biomedical Engineering, National Taiwan University, Taiwan.
Abstract:
We report a multi parameters cardio-pulmonary (CP) monitoring system with features of low power consumptions (30mA,3.3V), miniaturization (size 25 cm2), and wireless data communications (Frequency 96 MHz) for wearable applications in e-Health. Its target application is forthe evaluation of fitness of CP during exercises. We use aminiature bi-directional hot-wire sensor for respiratory function,an optical sensor for saturated blood oxygen level or plethsymograph, and two surface electrodes for single lead electrocardiograph. The fitness indexes include blood oxygen level, ECG, and respiratory functions, which will be used for the quantitative evaluation of the level of physical activity.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...