Related Experiment Video
Updated: Jul 17, 2026

"Liver-on-a-Chip" Cultures of Primary Hepatocytes and Kupffer Cells for Hepatitis B Virus Infection
Published on: February 19, 2019
An artificial liver sinusoid with a microfluidic endothelial-like barrier for primary hepatocyte culture
Philip J Lee1, Paul J Hung, Luke P Lee
1Department of Bioengineering, Biomolecular Nanotechnology Center, Berkeley Sensor and Actuator Center, University of California-Berkeley, Berkeley, CA 94720-1762, USA.
Abstract:
Primary hepatocytes represent a physiologically relevant model for drug toxicity screening. Here, we created a biologically inspired artificial liver sinusoid with a microfluidic endothelial-like barrier having mass transport properties similar to the liver acinus. This unit consisted of a cord of hepatocytes (50 x 30 x 500 microm) fed by diffusion of nutrients across the microfluidic endothelial-like barrier from a convective transport vessel (10 nL/min). This configuration sustained rat and human hepatocytes for 7 days without an extracellular matrix (ECM) coating. Experiments with the metabolism mediated liver toxicant diclofenac showed no hepatotoxicity after 4 h and an IC(50) of 334 +/- 41 microM after 24 h.