Related Experiment Video
Updated: Jul 17, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Attomole catechins determination by capillary liquid chromatography with electrochemical detection
Akira Kotani1, Kouji Takahashi, Hideki Hakamata
1School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Horinouchi, Hachioji, Tokyo, Japan.
Abstract:
Attomole quantities of catechins were determined by a capillary liquid chromatography system with electrochemical detection (CLC-ECD) and the system is applied to the determination of catechins in human plasma. The eight catechins: catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg), and epigallocatechin gallate (EGCg), were separated within 10 min using a capillary column (0.2 mm i.d.) and a mobile phase of phosphoric acid (85%)-methanol-water (0.5:27.5:72.5, v/v/v), and were detected at +0.85 V vs. Ag/AgCl. Peak heights were found to be linearly related to the amount of catechins injected, from 200 amol to 500 fmol (r > 0.998). The detection limits of the catechins were 61 amol for EGC, 75 amol for EC, 54 amol for GC, 61 amol for C, 67 amol for GCg, 75 amol for EGCg, 75 amol for ECg and 89 amol for Cg (S/N = 3). Because the present method is highly sensitive and allows facile pretreatment for plasma sample, the time courses of concentrations of catechins (GCg, EC, EGCg, ECg, and Cg) and their conjugates in human plasma obtained from a 10 microl plasma sample after ingestion of green tea could be determined.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...