Related Experiment Video
Updated: Jul 17, 2026

Generation and Grafting of Tissue-engineered Vessels in a Mouse Model
Published on: March 18, 2015
Implantation of decellularized small-caliber vascular xenografts with and without surface heparin treatment
Xue-Ning Wang1, Chang-Zhi Chen, Min Yang
1Department of Cardiothoracic Surgery, Renji Hospital, Shanghai Jiaotong University Medical College, Shanghai, China.
Abstract:
Heparin treatment of decellularized xenografts has been reported to reduce graft thrombogenicity. However, little is known about the in vivo comparison of heparin-treated with non-heparin-treated xenografts, especially for small-caliber vascular implants. We implanted either a heparin-treated or a non-heparin-treated canine carotid artery as bilateral carotid xenograft in rabbits (n = 24). Small-caliber xenografts (3 approximately 4 mm) were decellularized by enzymatic and detergent extraction and were further covalently linked with heparin. During implantation, thrombosis rate was 4% in the heparin-treated xenografts and 25% in the non-heparin-treated xenografts after 3 weeks (P < 0.05). After 6 months, it was 8 versus 58%, respectively (P < 0.01). Both heparin-treated and non-heparin-treated xenografts harvested at the end of 3 and 6 months showed a satisfactory cellular reconstruction of either smooth muscle cells or endothelial cells. These results indicate that heparin treatment of the small-caliber decellularized xenograft reduces the in vivo thrombogenicity. Both heparin-treated and non-heparin-treated xenografts seem to undergo a similar cellular remodeling process up to 6 months.