Related Experiment Video
Updated: Jul 17, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Total lung capacity: single breath methane dilution versus plethysmography in normals
Gene R Pesola1, Robert T Magari, Samuel Dartey-Hayford
1Division of Pulmonary/Critical Care Medicine, Department of Medicine, Harlem Hospital/Columbia University, New York, New York, USA. grp4@columbia.edu
Objective And Background:
Methane is an inert tracer gas used to obtain TLC estimates during single breath diffusion capacity (DL(CO)) measurements. The aim of this study was to assess the accuracy of methane dilution TLC in normal subjects undergoing single breath diffusion capacity measurements using plethysmography as the gold standard comparison method.
Methods:
Fifty non-smoking adults underwent lung function testing. Total lung volume was obtained by both plethysmography and methane dilution during a single breath DL(CO) measurement. Deming regression and the concordance correlation coefficient, r(ccc), were used to determine agreement between methods for TLC. Bias was the mean difference between methods and limits of agreement were the mean difference between methods +/- 1.96 (SD). All values are mean +/- SD unless otherwise stated.
Results:
Plethysmography and methane dilution TLC values were not significantly different. The r(ccc) was 0.87 (95% confidence interval (CI) 0.78-0.92). Deming regression revealed a slope of 0.93 (P = 0.17, H(o): beta = 1.0; 95% CI 0.84-1.03) and a y-intercept of 0.20 (P = 0.39, H(o): alpha = 0; 95% CI -0.27-0.70). The bias was 0.11 L favouring plethysmography. Limits of agreement varied as 0.11 +/- 0.92 L.
Conclusions:
There is statistical agreement between methods suggesting the average TLC by methane could substitute for plethysmography in normals at the population level. At the individual level, a normal methane dilution value indicates a normal TLC whereas values below the normal range should be validated using plethysmography.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Lung Capacity
Respiratory Volumes and Capacities
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...