Related Experiment Video
Updated: Jul 16, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
An accurate and easy procedure to obtain isothermal Kováts retention indices in gas chromatography
José Antonio García-Domínguez1, Rosa Lebrón-Aguilar, Jesus Eduardo Quintanilla-López
1Instituto de Química-Física Rocasolano, Consejo Superior de Investigaciones Cientificas, Madrid, Spain.
Abstract:
Isothermal Kováts retention indices may be used in GC for identification purposes, but they are also useful in characterisation of stationary phases and for studying structural and physico-chemical properties of both the analyte and the stationary phase. They are currently reported as whole numbers with an accuracy of one index unit for non-polar stationary phases. The method recommended for their calculation uses a linear regression model, although non-linear models have also been applied with good results. In both cases, a computer programme and the retention times of a series of n-alkanes that elute correctly and resolved from the other compounds are needed, conditions which cannot always be fulfilled. However, it is possible to calculate retention indices with an accuracy of 0.1 retention index units (0.2 units for packed columns) with the help of only three n-alkanes using just a pocket calculator or a computer spreadsheet. The main requirement is that at least one of the n-alkanes has a retention index differing by no more than one hundred retention index units from that of the analyte being investigated. Examples are given for different stationary phases.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
