Related Experiment Video
Updated: Jul 16, 2026

Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
Sequential determination of Pu and Am radioisotopes in environmental samples; a comparison of two separation
Rozle Jakopic1, Polona Tavcar, Ljudmila Benedik
1Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia. rozle.jakopic@ijs.si
Abstract:
Two separation methods for the sequential determination of Am and Pu radionuclides are presented and the results obtained are compared. Analysis involves leaching the sample with concentrated nitric acid (HNO(3)), followed by radiochemical separation using extraction chromatographic resins (UTEVA, TRU) and anion exchange. Sources for alpha spectrometry were prepared by micro-precipitation on neodymium fluoride (NdF(3)). The chemical recoveries were determined using (242)Pu and (243)Am tracers. The methods were tested on reference materials and on two sediments. All the results were in good agreement with the reference values. The evaluation of uncertainty is also included.
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab