An Alternative to the Traditional Cold Pressor Test: The Cold Pressor Arm Wrap
Published on: January 16, 2014
Assessment of cardiac contractility during a cold pressor test by using (dP/dt)/P of carotid artery pulses
Kayo Moriyama1, Hirotoshi Ifuku
1Graduate School of Education, Kumamoto University, Kumamoto 860-8555, Japan.
Abstract:
The ratio of the first derivative (dP/dt) of a carotid artery pulse to the developed pressure (P), (dP/dt)/P, is an easily measurable, noninvasive index of cardiac contractility even in moderate exercise. We examined the effects of transient cold exposure on cardiac contractility in normal reactors (n = 12) and hyperreactors (an increase in systolic or diastolic pressure >15 mm Hg; n = 6) by using this index. Eighteen healthy participants were subjected to the cold pressor test, which required them to immerse the right hand in chilly water (4 degrees C) for 2 min. Although cold stress maximally increased mean blood pressure during the second minute, it maximally increased heart rate and cardiac contractility after 60 s of immersion in both groups of subjects. Comparing normal reactors and hyperreactors by two-way ANOVA revealed a group x time interaction for heart rate but not for cardiac contractility. These findings suggest that the increase in cardiac contractility during cold-water immersion dose not reflect the levels of heart rate and muscle sympathetic nerve activity, and that the specific responses of cardiac function to a cold pressor test in hyperreactors depends on heart rate rather than cardiac contractility.
More Related Videos
09:33A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pulse
The pulse serves as a clinical indicator...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of blood pressure in brachial artery(two-step method)