Related Experiment Video
Updated: Jul 16, 2026

Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
Damage accumulation and fatigue life of particle-abraded ceramics
Yu Zhang1, Brian R Lawn, Kenneth A Malament
1Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, New York 10010, USA.
Purpose:
This investigation compared initial and fatigue strengths of particle-abraded ceramics to those of as-polished alumina and zirconia ceramics in crown-like layer structures.
Materials And Methods:
Alumina or zirconia plates bonded to polycarbonate substrates were subjected to single-cycle and multi-cycle contact (fatigue) loading. Cementation surfaces of the ceramic were damaged by controlled particle abrasion, indentation with a sharp diamond at low load, or a blunt indenter at high load. The stresses needed to initiate radial fractures were evaluated.
Results:
The strengths of specimens were lowered by fatigue loading. After the equivalent of 1 year of occlusal contacts, the strengths of undamaged specimens degraded to approximately half of their single-cycle values. In particle-abraded specimens, an additional 20% to 30% drop in strength occurred after several hundred load cycles. Particle abrasion damage was approximately equivalent to damage from sharp indentation at low load or blunt indentation at high load.
Conclusion:
Damage from particle abrasion, not necessarily immediately apparent, compromised the fatigue strength of zirconia and alumina ceramics in crown-like structures. In fatigue, small flaws introduced by particle abrasion can outweigh any countervailing strengthening effect from compression associated with surface damage or, in the case of zirconia, with phase transformation.
Related Concept Videos
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Fatigue
Toughness and Hardness of Aggregate
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Unsoundness of Aggregate due to Volume Change
Fatigue Strength of Concrete